WD20NMVW 1823 SHREK HDD Repair and Data Recovery Steps

,

This is one typical western digital hard drive firmware repair and data recovery case study.

Patient HDD iD:

WD20NMVW-11W68S0
PCB: 2060-771823, originally 2060-771801
Family: SHREK
SPT:1437
Head number: 8

Failure symptoms:

Undetected, SED

HDD Repair tools and Data recovery tools required in this case study:

DFL-WD hdd repair tool
DFL-DDP data recovery tool

HDD Repair and Data Recovery Steps:

01: Enter DFL-WD firmware repair software by kernel mode;
02: Backup Rom and disable 02;
03: Restart firmware and re-enter the program;
04: Fix slow issue by ABA;
05: Test firmware modules and key modules are all good;
06: Open DFL-DDP data recovery software, one click to decrypt the data;
07: Set up one file extraction project, and all the lost folders and files were listed and available for data recovery.