Seagate ST2000LM007 HDD Head Damage and Data Recovery
This Seagate ST2000LM007 is one patient HDD from one DFL user in India.
The patient HDD was reported without clicking noises and spinning well, the user thought it was firmware corruption issue, but actually it is not.
The following were the error messages:
”
Boot 0x80M
Tech Unlock Handshake: 0xA3A8EDEB
Reply:
QB
Rst 0x80M
Srv DETCR init 0x0000
SCTTable Corrupt
(P) SATA Reset
RAW OFF
PASS
(P) SATA Reset
RAW OFF
SIM Error 3005 LBA 0000000000005783 FD FC378093
RW Error 00000080
DOS:0 Scan Unit
FAIL Servo Op=0195 Resp=0007
0195 642E 0004 7FFF 7FFF 7FFF 0000 0003 0000 0000 03E8 0000 FFFF 8860 0000 0000 0054 02FF
UnvRdStatus1: 0x00004500
UnvScntLdData: 0x00000032
SrvVrtSectNum: 0x00000123
MmValidServo: 0x00000000
MmExtServoNum: 0x000000392871 0000 0000 65A0 6666 A000 0000 0000 0000 0000 0000 0000 0000 0000
ResponseFrame 0000 0001 FFFF FF23 FE64 0000 FB65 0000 0166 0000 FA66 0000 F766 0000 1A7E 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0031 Loop=2247
FAIL Servo Op=06DF Resp=0007
06DF 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
ResponseFrame 000F B200 F8A4 0126 EE00 0A10 F501 6094 EEB8 0AC0 F708 FE26 F604 01BC F201 40AC F708 FE20 F504 6380 EDD3 0A2A ED93 1A2B EEB4 0AE0 EEF1 FA10 BFC8 EEB0 0000 0000 0000
DSC FAIL
FAIL Servo Op=0195 Resp=0007
0195 642E 0004 7FFF 7FFF 7FFF 0000 0003 0000 0000 8000 0000 FFFF 8860 0000 0000 0054 02FF 2871 0000 0000 65A0 6666 A000 0000 0000 0000 0000 0000 0000 0000 0000
ResponseFrame 0002 0001 0001 B23B EE00 0A10 F501 6094 EEB8 0AC0 F708 FE26 F604 01BC 1C42 40AC F708 FE20 F504 6”
The FAIL Servo Op=0195 Resp=0007 keeps coming and never end and the hdd doesn’t enter F3 T> at all.
The is actually the heads damage, exactly speaking, the heads were downgraded and very weak and cannot read the platter surfaces properly at all.
So users need to use Seagate LM Slim HDD Head Comb Suite.Advanced to separate the heads and swap the heads with donor ones in clean room.