Hello Dolphin,
I ask that the device turkey to get shipping transaxle.
I will be glad if you give me more information about the price of your data recovery tools.
thank you Read more
Hello Dolphin,
I ask that the device turkey to get shipping transaxle.
I will be glad if you give me more information about the price of your data recovery tools.
thank you Read more
Estimados señores, estoy interesado en especializarme en la reparación de datos
He sufrido perdidas terribles y las “especialistas” la verdad no pueden.
Asi que he decidido ampliar los servicios técnicos que doy
Agradeceria puedan proveerme los costos del hardware y software necesario.
Gracias
This is one Hitachi patient HDD data recovery case study from one DFL user in Colombia.
HDD ID: Hitachi HDS721050CLA662
Capacity: 500GB
When this hdd was received, the drive was not detected and no data was available for data recovery. Read more
This is one Western Digital HDD data recovery case study from one DFL user in India.
When this patient HDD was connected to DFL-SRP WD hdd repair tool, the patient HDD could be slowly ready, but had error of 0A 0B read failure and all firmware modules read failure. Read more
Hi Stanley, the drive is failing to read after around 2% of the drive. All sectors red colour. Starting LBA of RW Request=00007DE280 Length=FFFFFFFF
ProcessRWError -Read- at LBA 00007DE280 Sense Code=44090082
Read more
“MCMT table is corrupted” is one very common firmware error output in the COM terminal. The following patient HDD is one firmware corrupted case from one Italian DFL user.
The following are the detailed error messages:
Tech Unlock Handshake: 0xC66A98E3 Read more
Please be kindly informed that Dolphin Data Lab Headquarter will be closed for Chinese National Day and Middle Autumn festival from October 1st to October 8th. Our office will re-open for business on Friday, October 9th 2020.
Here are some important notes about our work arrangement during this 8 day holiday. Read more
This Seagate patient HDD was recovered fully by Dolphin remote data recovery system and the user is one Indian DFL user. When the user connected the patient HDD to DFL-SRP Seagate HDD firmware repair tool, powered on the HDD and got the “SP Regen FAIL, Update Mask” error and cannot enter F3 T>. Read more
This WD40EZRZ-00WN9B0 patient hard drive data recovery case study is done for one DFL user in Italy, the PCB number is 2060-771945-002.
After connecting the patient hard drive to DFL WD firmware repair hardware, the drive was not detected but the drive could be ready. Read more
As for Western Digital undetected or capacity 0 or wrong capacity hard drives, they are mostly firmware corrupted hard drives. The case study to be discussed today is from one DFL user in USA and the patient HDD model number is WD20EZRZ-00Z5HB0. Read more
Chengdu Headquarter: 1631/1632, BaoLiYunShang, HuAnNanLu, Longquanyi District, ChengDu 610100, Sichuan Province, China
QQ: 428306801
Skype: dolphin.data.lab
Phone: 0086-28-64737668
Email: [email protected]