This is one successful western digital undetected hard drive firmware repair and data recovery case study from one DFL user in India.
Patient HDD ID:
Model number: WDC WD20NPVZ-00WFZT0
Serial Number: WD-WXN1A776ZHTN
Capacity: 1863GB
Head number: 8
SPT: 1480
Family: SHREKLT
Patient HDD Failure Symptoms:
Undetected/data inaccessbile
Hard Drive Firmware Repair Tools and Data Recovery Hardware Tools Required:
DFL Western Digital HDD Repair Tool
DFL DDP Data Recovery Equipment
Hard Drive Firmware Repair and Data Recovery Steps:
Backup ROM;
Disable 411 and restart firmware;
Refresh hdd ID;
Backup hard drive firmware modules (important modules);
Slow fix-mode 1;
Enable 411 and restart firmware;
Refresh hdd ID;
Open DFL-DDP data recovery equipment and software;
Set up head map and image good heads and good sectors and then weak heads and sectors;
Finally all lost data was recovered from the faulty WD hard drive.
Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab
This is one nice data recovery case study from one DFL user in India, the patient drive is firmware locked and the data area is not accessed.
Model : ST1000VX005-2EZ102
Serial : Z9CC69D2
Firmware : CV11
Capacity : 1953525168 (931.51GB)
Sector size : 4096
Heads number : 2
Rst 0x40M
2Sync:01 0E
EDAC Value = 00000000FFFFFFF5
EDAC Value = 00000000FFFFFFF5
Retry delay
EDAC Value = 00000000FFFFFFF5
EDAC Value = 00000000FFFFFFF5
Retry delay
LD: Size:00000028 HBlocks:0000 Size:002BD17F HBlocks:0032 Size:00282A49 HBlocks:0032 FlashRestore 00000000 00000028 ECBD
PP: Size:0000B400 HBlocks:0000 FlashRestore
PVTSize: 000150C8 CompSize: 000002B2 DeCompSize: 000150C8 00000000 000002B2 9E03
2Sync:00 04
DSP022B
No HOST FIS-ReadyStatusFlags 0002A1A1
2Sync:01 0C
Boot 0x40M
SpinUp
RECOV Servo Op=0100 Resp=0005
RECOV Servo Op=0055 Resp=0005[LBA=0x00006B6F]N[LBA=0x00006C28]N0[LBA=0x00006D5D]N0[LBA=0x000070A1]N0[LBA=0x000070C2]N0[LBA=0x0000737C]N0[LBA=0x000073EB]N0[LBA=0x000074EE]N0[LBA=0x00007500]N0[LBA=0x0000775C]N0
Trans
Rst 0x40M
2Sync:01 0E
2Sync:01 0E
2Sync:01 0E
2Sync:01 0E
2Sync:01 0E
(P) SATA Reset
LD: Size:00000028 HBlocks:0000 Size:002BD17F HBlocks:0032 Size:00282A49 HBlocks:0032 DiscRestore 00000000 00000028 04ED
PP: Size:0000B400 HBlocks:0000 DiscRestore
PVTSize: 000150C8 CompSize: 000002B2 DeCompSize: 000150C8 00000000 000002B2 9E03
2Sync:00 04
DSP022C^c
ASCII Diag mode
F3 T>^l
Diagnostic Port Locked
To fix above patient drive, the user used DFL Seagate hdd repair tool to backup rom, generate unlock rom, write unlock ROM, power off and on, send unlock key, backup important SYS files, clear g-list, regenerate translator, etc.
After fixing the firmware area, the users tested the data area and found there’re some bad sectors in the front, the middle and ending parts of data areas were accessible.
The user set up head map, edited the LBA range to image the patient hdd by heads within DFL-DDP data recovery equipment and finally most data was recovered, only some system files were missing which are not important at all.
Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab
Dolphin Data Lab has released the new DFL all in one data recovery software V20230301 to work with the data recovery hardware tools.
The new V20230301 data recovery software has been uploaded to DFL user-only forum and users can login the forum to upgrade to the latest. It’s strongly recommended for all DFL users to upgrade to latest for the best firmware repair and data recovery success rate.
What’s new in this new software upgrade?
01: ST8000NM0105 G001 G004 Firmware Repair Support Added to DFL Seagate HDD Repair Tool, other firmware versions can be unlocked with old software. There’s now a new mode option-Mode 2 when users are trying to generate the unlock ROM, users need to select mode 2;
02: Seagate SMR hdd format data recovery such as rosewood EB01 format recovery;
03: Seagate weak head repair for new F3 families for data recovery purpose, it is very helpful for some weak head cases which don’t require head swap;
04: DFL-DDP image setting enhancement: enhance success rate for the following drives and cases:
WD SMR drives with all sectors 0000, Seagate drives SEDU, 241A, etc.
05: Full firmware repair and data recovery software codes improvement to get the software working more smoothly and excellently;
…
Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab
This is one Seagate Rosewood portable hard drive-ST2000LM007 and when our engineer was trying to backup the firmware modules, it’s very slow with some slight noises.
It seems like some noises from the heads, seems like some kind of damage on the heads but actually not.
Patient HDD ID:
Model number: ST2000LM007-1R8174
Serial number: WDZVJ06Z
Firmware: EB01
Capacity: 3907029168
Sector Size: 4096
Heads number: 4
Family: Janus (AF)
ST2000LM007 Error messages:
Rstᅠ0x80M
T:0x0000 0x3FFFFFFF
FTU
TCC:0014:001D EMCDataErr:0000000C
PrgF
(P)ᅠSATAᅠReset
RAWᅠOFF
ᅠPASS
ᅠBothᅠcopyᅠisᅠsame!ᅠᅠᅠLPCDisc=01ᅠ1A326711ᅠ00C5
PrgF
6GbᅠMaxᅠSpeedᅠloweredᅠtoᅠ3GbᅠforᅠIntelᅠbug
SendᅠStatus:ᅠCOMRESETᅠseen
CSpd=ᅠ3Gbps
FIS34ᅠ
IDLE1
VC0
XI2
VC1
VC2Up
IDLE2
VC0
VC1
VC2Up
XI2
TCC:0014:0019 EMCDataErr:00000000
FAFH_TRIGGER_POWER_UP
IDLE2
VC0
It’s very easy to fix above firmware failure and get the ST2000LM007 patient hdd repaired by DFL Seagate hdd repair tool.
All users need to do is to go to the ‘Defects Management’>Initialize ID (ATA) and it’s just one simple click to fix above issue.
Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab
What’s new in Dolphin DVR V3.68?
Get the latest Dolphin CCTV DVR data recovery software here.
* Dongle ID and license valid date are required for this update.
New Camera Video Support
Canon EOS 500D professional camera video recovery support;
Canon PowerShot SX160 IS professional camera video recovery support;
Canon ixus_190 professional camera video recovery support;
Canon ixus_285_HS professional camera video recovery support;
Canon powershot_a2300 professional camera video recovery support;
Canon powershot_a3300_is professional camera video recovery support;
Canon EOS 5D Mark II professional camera video recovery support;
Canon IXUS 220 HS professional camera video recovery support;
Canon IXUS 230 HS professional camera video recovery support;
Canon IXUS 1000 HS professional camera video recovery support;
Canon PowerShot A3400 IS professional camera video recovery support;
Canon PowerShot G12 professional camera video recovery support;
Canon PowerShot SX30 IS professional camera video recovery support;
Canon PowerShot SX150 IS professional camera video recovery support;
Nikon CoolPix S8200 professional camera video recovery support;
Nikon E4100 professional camera video recovery support;
Nikon s9100 professional camera video recovery support;
NIKON COOLPIX S6 professional camera video recovery support;
NIKON D7200 professional camera video recovery support;
Nikon L120 professional camera video recovery support;
NIKON D7000 professional camera video recovery support;
Konica Minolta SX744 professional camera video recovery support;
Sony hxr_nx80 professional camera video recovery support;
GoPro Hero5 Black professional camera video recovery support;
CASIO EX-TR150 professional camera video recovery support;
KODAK V550 professional camera video recovery support;
KODAK Z1012 IS professional camera video recovery support;
Kodak DX7440 professional camera video recovery support;
SANYO E10 professional camera video recovery support;
SANYO S7 professional camera video recovery support;
Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab
This is one more successful Seagate ST1000LM035 undetected LED HDD firmware repair and data recovery case study from one DFL user in Indonesia.
Patient HDD ID:
Model number: ST1000LM035 1RK172
Family: Rosewood A5
HDD Repair Tools and Data Recovery Equipment Required:
DFL-SRP USB3.0 all-in-one Data Recovery Equipment
Error Messages within COM Terminal:
‘Boot 0x80M
QB
Rst 0x80M
Srv DETCR init 0x0000
FTU
(P) SATA Reset
RAW OFF
PASS
(DOS Table) Worst Count: 00000FF8 At SU: 0000523E NT: 00000000 OT: 000000C5
(MC POR Duration): 000000007B
Intel 6G->3G
Send Status: COMRESET seen
CSpd= 3Gbps
DSC
Update Mask – 000000000D0A3EB8 – 00000008 – 00
Update Mask – 000000000D0A3EC0 – 00000008 – 00
Starting LBA of RW Request=0001A13C9F Length=00001DD0
ProcessRWError -Read- at LBA 0001A147F9 Sense Code=43110081
Common path start quit now
ProcessRC: 00000000,00000000
SkipLen: 00000000
ReadContinuous: 01A1468F,00000350
UnrecovSectorCount:002B,0236
NumUDEs: 0000002B,00000031,00000236
Passed: 00000080,00000153,000002FB
Out:
PrgF
LED:0x000000BD FAddr:0x0000780F
LED:0x000000BD FAddr:0x0000780F
LED:0x000000BD FAddr:0x0000780F’
Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab