Dolphin Data Lab has released the world’s top data recovery assisting tool-Dolphin DR Assistant Pro. and Dolphin DR Assistant Pro. is Dolphin’s first software-only tool. Whatever data recovery tools you are using, Dolphin DR Assistant Pro. can help to enhance data recovery efficiency and data recovery success rate.

Dolphin Data Recovery Assistant Pro. contains 6 modules:

01: Invalid Files;
02: Extension;
03: N.S Image;
04: Database Repair;
05: Raid Analysis;
06: File Rename.

The module ‘Invalid Files’ is used to organize the data for data recovery cases with many bad sectors, weak heads, scratched surfaces, etc. When the data was recovered from these cases, many files are corrupted and there’re also some other invalid files too within the recovered data. At this time, Dolphin DR Assistant can be used to find out the invalid files, delete empty folders, delete invalid files of ‘tmp’, ‘tem’, ‘temp’, ‘~’, ‘?’, ‘Ink’, delete files if ‘DEADDEAD’ accounts for 50% or above of files’ hex data. Besides, users can delete the invalid files according to file types.

Module ‘Extension’ is specially used to correct the file extensions by changing the wrong extensions to the original correct extensions. For example, users can easily correct the .chk files in ‘FOUND’ folders to normal recognized file extensions so that users can open the files successfully.

‘N.S Image’ module is used to image the drives with non-standard sector sizes of 518, 520, 522, 528, etc to target drives or to a file with standard sector size of 512 bytes. Drives with non-standard sector sizes are usually used in NetApp, EMC, HP, Hitachi/IBM high-end storage devices, common data recovery tools cannot even analyze them or image them. These drives appear as server Raid drives and therefore, users need to image all of the drives and analyze them, find out the necessary parameters, rebuild the raid array and finally get lost data back. During the recovery process, the conversion from non-standard sector sized hdds or image files to standard sector sized ones is very important and this is why users need to use Dolphin DR Assistant ‘N.S Image’ module.

‘File Rename’ software module is very helpful in many data recovery cases. When the files lose their original names by raw recovery, recovery by file types, virus’s malicious modification, etc, users can use Dolphin DR Assistant to rename those files by extracting the date, Sheet name(excel), content, size. Our engineers are usually using ‘content renaming method’ frequently so that we can easily find out the wanted files we need.

‘Raid Analysis’ module is specially designed to generate one detailed engineering log report file which contains the parameters of ‘Disk Order’, ‘Raid Type’, ‘Block Order-Left/Right, Synchronous/Asynchronous’, ‘Block Size’, ‘Parity Delay’, etc. For skilled raid recovery engineers, it takes several minutes to find out those parameters from the engineering report file and then it’s easy to rebuild raid array and find all lost data back. Without this file, it may take several hours or longer and very complicated for some raid types and cases and it is not possible to get the raid cases fixed for beginners!

‘Repair DB’ module is mainly used to repair SQL Server corrupted databases. All users need to do is to select the corrupted database, select the repaired database save path and add the backup database and then the ‘Repair DB’ software will automatically repair the damaged database and save them.

  • The ‘Repair DB’ software module is mainly for repairing corrupted databases caused by bad sectors or scratched surfaces.

Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab

With DFL Seagate HDD firmware repair tool, users can easily fix the Seagate firmware corruption and get lost data from Seagate undetected or wrongly detected hard drives. The following is one successful data recovery case study from one DFL user in Indonesia.

The patient HDD was detected with capacity 0 and it’s not possible to access the data area.

Model : ST4000DM004-2CV104
Serial : ZFN1DWGH
Firmware : 0001
Capacity : 7814037168 (3726.02GB)
Sector size : 4096
Heads number : 4

FW info : Obtained
FW version : V0A84C279.DPC7.AF0055.0001
FW package P/N :
FW ID : 00352241
FW creation date : 2017/09/20
FW creation time : 02:50:11
CFW version : V0A84C279.DPC7.AF0055.01326721.0
SFW1 version : 0352241.0001

Modules list : Obtained
Modules number : 57

F3 T>^l
V11 CheopsLiteA SATA 2.0 RAP30.6.2 SMR 2MB Flash 250 zn zonedse
Product FamilyId: 9B, MemberId: 01
HDA SN: ZFN1DWGH, RPM: 5426, Wedges: 240, Heads: 4, OrigHeads: 4, ActiveHdMap: 000F, Lbas: 00003ADABD42, PreampType: 82 10
Bits/Symbol: C, Symbols/UserSector: CB6, Symbols/SystemSector: CB5
PCBA SN: 0000M8367P7K, Controller: CHEOPSLITE_1_0_SATA(1410), Channel: Unknown, PowerAsic: Unknown Rev 00, BufferBytes: 10000000
SF ID: EF 60, SF Part Size: 800, Flash Used: 800
Package Version: V0A84C279.DPC7.AF0055.0001 , Package P/N: ———, Package Global ID: 00352241,
Package Build Date: 09/20/2017, Package Build Time: 02:50:11, Package CFW Version: V0A84C279.DPC7.AF0055.01326721.00352241.0001 ,
Package SFW1 Version: 7924, Package SFW2 Version: —-, Package SFW3 Version: —-, Package SFW4 Version: —-
Controller FW Rev: 09200250, CustomerRel: 0001, Changelist: 01326721, ProdType: V0A84C2.DPC7QC, Date: 09/20/2017, Time: 025011, UserId: 00352241
Servo FW Rev: 7924
TCG IV Version: 30.05
Package BPN: 6300
RAP FW Implementation Key: 1E, Format Rev: 0206, Contents Rev: 1F 80 02 00
Active BFW Container: 0
4K Sys Area: 1
Features:
– IOEDC enabled
– IOECC enabled
– DERP enabled v. 6.0.00.0000000000000001
– LTTC-UDR2 disabled
– SuperParity 4.1 enabled
– Humidity Sensor disabled
– Media Cache Partition enabled
– Media Cache enabled
– Low Current Spin Up Normal
– Ready Sequence Optimization enabled
– Torn Write Protection enabled
– SubRelease:0
– Critical Event Log v. 1
– FAFH 40.11 disabled
– EWP:0
– DRAM Mirror:0

The Dolphin engineer helped to access the F3 T> and then backup the important SYS files/firmware modules.

Next the engineer cleared g-list, smart and regenerated translator. The engineer has checked the NGlist entries before and after the translator regeneration to make sure the translator regeneration generates positive result.

Next the engineer fixed the media cache issue.

Next the engineer opened the DFL-DDP data recovery equipment and set up one file extraction project, all lost data was perfectly recovered.

 

Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab

This is one very interesting CCTV DVR format video data recovery case study for one DFL user from India. This case was given to other data recovery companies with other CCTV DVR data recovery software but failed.

With any other CCTV DVR data recovery software tools, the users can only get videos of only 2MB or the videos are in a mess with different cameras in one video, so no effective videos at all.

This kind of failure is usually caused by the original dvr device format and about 500mb data in the beginning of the dvr drive is lost and therefore, users cannot find any effective/valid videos.

When this case was given to Dolphin user with Dolphin DVR Pro, the user applied for one remote support by Dolphin remote data recovery system. Dolphin engineer helped the user to find the starting address of the data area by Dolphin DVR Pro. and then started the video analysis in fast analysis mode and finally all cameras and videos were found and listed properly.

Users can select the cameras and videos to save. and in the coming new Dolphin CCTV DVR data recovery software, Dolphin DVR Pro. can search the data address automatically when it is lost and then it is more convenient.

Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab

HDD Platter Cleaning Workstation Pro. is one hardware-only equipment for data recovery purpose, it is specially designed to clean both 2.5 and 3.5-inch hard drive platters.

About the Torque Used by HDD Platter Cleaning Workstation Pro.

Compared with the HDD motor torque, HDD platter cleaning workstation Pro. Uses lower torque for platter cleaning purpose.

HDD motor can use higher torque because there’s flying height between heads and platters and it’s safe to spin the motor and get the heads to read and write properly. But for platter cleaning, it is totally different story:

When the platter surfaces are contaminated with dust, finger prints or other contamination, users must use lower torque cleaning toolkit and users cannot push hard to clean or never give too much pressure to the platter surface, any exceeded pressure on the surface contamination(dust or other particles) may cause scratches or permanent data loss. Dolphin engineers have tested a lot of motor torque options and then fixed one best working torque to spin the platter for platter cleaning purpose.

During the video instructions, users can see how our engineers are cleaning the platters properly with smart slight pressure by the cotton swab with or without absolute alcohol for the two types of cleaning cases.

HDD Platter Cleaning Workstation Pro. contains the following components:

1, Cleaning hardware workstation;
2, Platter fix nut for 2.5″ platter;
3, Platter fix nut for 3.5″ platter;
4, Power Supply AC Adapter.

Any question is welcome to [email protected] or Add dolphin official skype ID: dolphin.data.lab

This data recovery case study is shared by one of our experienced, smart, friendly and kind users from Sri Lanka, his name is Dananjaya who offers very professional data recovery services in Sri Lanka.

HDD ID Information:
Patient drive: WD20EZAZ
PCB: 2060-810011

Reported symptoms
According to the drive owner, when he was copying wedding pictures to HDD, windows OS popup error massage called “not enough space”

HDD Repair and Recovery steps:

1.Once our user received the HDD, he checked. He found that when power on HDD, it spin up, but then two times’ clicking and power down. Like platter damage;
2.He tried to unlock, but same scenario. No modules showed, only power up, two clicks, power down;
3.So he guess it can be module damaged. But couldn’t power up. He used only pcb and disable module 02, module 411 and kernel mode. But same clicking;
4.He found a donor PCB with same microcode HDD. Then used patient PCB to donor for test, donor drive can be detected as normal;
5.He put donor to PAITENT HDD. Luckily the patient drive can be detected. But after 10 seconds, gave one click and went to busy status. Not responding;
6.He managed to power on and off till enter the inside of FW program;
7.He disabled module 02. After doing that HDD shows module and no clicking. But once enabling module 02, start clicking again. He had to disable again to get all modules;
8.He edited module 02 manually and write it SA. Fortunately no clicking, smoothly worked with HEX 00;
9.DFL repaired the corrupted module 190, he then wrote it to SA and load to RAM. “missing node function ” and “repair nodes function” which built in version 2.31 were used for this case;
10. Two partitions are displayed properly, the image speed is quite good, up to 150M per second.

HDD Repair and Data Recovery Equipment used in this data recovery case study:

DFL WD HDD Repair Equipment
DFL-DDP Data Recovery Equipment

Welcome to send your questions or enquiry to [email protected] or add Dolphin Skype ID: dolphin.data.lab for any consultation.

How to recover lost data from WD SMR 800077 Carmel patient hard drives?
2060-800077-003 HDD Family: CARMEL

WD CARMEL HDD Failure Types:

SED lock and MCU lock;
Weak heads
Slow issue by firmware corruption;
All sectors 0;
Inaccessible data area;

Common Functions to be used to repair and recover lost data from WD SMR Carmel HDDs

HDD ROM chip pin reader to read/write ROM content;
MCU unlock ROM generation;
Disable 411;
Sector response time modification;
T2Data backup;
SMRzone backup;
190 backup, repair(Scan missing nodes, repair wrong nodes, delete overlapped nodes, etc ), write, ram loading(T2 auto loading);
Head map set up;
etc

WD CARMEL HDD Models:

WD60EDAZ-11BMZB0 2060-800077-003 REV P1
WD60EMAZ-51TKPB0 2060-800077-003 REV P1
WD60EZAZ-00ZGHB0 2060-800077-003 REV P2
WD60EFAX-68SHWN0 2060-800077-003 REV P1

WD20EZAZ-00GGJB0 2060-800077-003 REV P1

To repair and recover lost data from WD SMR Carmel hard drives, users need to have the following hdd repair tool and data recovery equipment:

HDD ROM Chip Pin Reader
DFL-WD HDD Repair Tool
DFL-DDP Data Recovery Equipment

WD SMR Carmel HDD Repair and Data Recovery Steps:
DFL-URE AND HDD ROM CHIP PIN READER HELP WITH EASIER WD SMR HDD FIRMWARE UNLOCK

Helpful links:

WD 2060-800077 WD20EZAZ HDD Firmware Unlock PCB

Any question is welcome to [email protected] or add Dolphin Skype ID: dolphin.data.lab